MECHANICAL
TEST ITEM SPECIFICATION
Resistance to There shall be Temperature profile of reflow soldering
Soldering heat no damage or
(reflow soldering) problems.
The specimen shall be passed through the reflow oven with the
condition shown in the above profile for 1 time.
The specimen shall be stored at standard atmospheric conditions
for 1 hour, after which the measurement shall be made.
ELECTRICAL
TEST ITEM SPECIFICATION TEST DETAILS
Insulation There shall be DC 100V voltage shall be applied across this sample of top
resistance no other surface and the terminal.
damage or
The insulation resistance shall be more than 1 × 10
8
Ω.
problems.
Dielectric There shall be AC 100V voltage shall be applied for 1 minute acrosset the top
withstand no other surface and the terminal of this sample
voltage damage or
problems.
Temperature
△L/L20℃≦±10%
The test shall be performed after the sample has stabilized in
characteristics
0~2000 ppm/℃ an ambient temperature of -20 to +85℃,and the value
calculated based on the value applicable in a normal
temperature and narmal humidity shall be △L/L20℃≦±10%.
Page-4/8
MSCDRI-2D14S-SERIES
soldering
(Peak temperature 260±3℃ 10 sec
Slow cooling
(Stored at room
temperature)
30 sec Min
+0
300
250
200
150
100
50
10
sec.
2 min. or more
Pre-heating
150 ~ 180℃
MAG.LAYERS
Commenti su questo manuale