ENVIROMENT CHARACTERISTICS
TEST ITEM SPECIFICATION
High temperature
L/Lo±5%
The sample shall be left for 96±4 hours in an atmospere with
storage
a temperature of 85±2 and a normal humidity.
There shall be Upon completion of the measurement shall be made after the
no mechanical sample has been left in a normal temperature and normal
damage. humidity for 1 hour.
Low temperature
L/Lo±5%
The sample shall be left for 96±4 hours in an atmosphere with
storage
a temperature of -25±3.
There shall be Upon completion of the test, the measurement shall be made
no mechanical after the sample has been left in a normal temperature and
damage. normal humidity for 1 hour.
Change of
L/Lo±5%
The sample shall be subject to 5 continuos cycles, such as shown
temperature in the table 2 below and then it shall be subjected to standard
There shall be atmospheric conditions for 1 hour, after which measurement
no other dama- shall be made.
ge of problems
table 2
Temperature Duration
25±3
(Themostat No.1)
Standard
atmospheric
85±2
(Themostat No.2)
Standard
atmospheric
Moisture storage
L/Lo±5%
The sample shall be left for 96±4 hours in a temperature of
40±2 and a humidity(RH) of 9095%.
There shall be Upon completion of the test, the measurement shall be made
no mechanical after the sample has been left in a normal temperature and
damage. normal humidity more than 1 hour.
Test conditions
The sample shall be reflow soldered onto the printed circuit board in every test.
Page-5/8
MSCDRI-2D14S-SERIES
No.1No.2
No.2No.1
1
2
3
4
30 min.
30 min.